Network Cable

Home » Products » Network Cable » Network Cable NC-2
Network Cable

Network Bridge Specifications of Network Cable :
Transmission speed: 100M (Kpbs)
Bandwidth support: 100MHz
Conductor diameter: 24AWG
Impedance: 100ohm
Traction force (drive force): 1000 (N)
Radius of torsion: 1 inch (4 times bigger than the cable diameter)
Pressure intensity resistance: >589
Environmental temperature: -20ºC-60ºC
storage Temperature: -20°C-80°C
Fire resistance degree CM
Weight of Network Cable 7002: 24ibs/mft
According to TIA/EIA-568 & ISO/IEC 11801
Frequency standard: UL444, TIA/EIA-568B
According to ROHS; PVC PE or LSOH cover
White cardboard packaging
Grey wire external cover

Network Cable Applications:
Ethernet 10 Base-T 100 Base-T4
Network signal transmission
ATM
TP-PMD Seppc Telephone
Multimedia Trunk Wring

Network Cable Construction (UTP CAT5):

Item No. Construction Conductor Dimension (mm) Core dimension (mm) No. Of pairs Nom. OD (mm) Cover type Note
112/212 UTP 0.50 0.91 4 5.3 PVC/PE
116-1/216-1 UTP 0.51 0.92 25 14.0 PVC/PE 4*6+1
116-2/216-2 UTP 0.51 0.92 25 13.0 PVC/PE 5*5

Electric Characteristics of Network Cable (UTP CAT6):

Frequency (MHZ) Impedance (ohm) RL (dB) Delay deviation
(ns/100m)
NEXT (dB/
100m)
ELFEXT (dB/
100m)
PS NEXT
(dB
/100m)
PS ELFEXT (dB/100m) Velocity of propagatio (m/s)
1 100±15 20 ≤45 74.3 67.8 72.3 64.8 0.6c
4 23 65.3 55.8 63.3 57.7
8 25 60.3 49.7 58.8 46.7
10 25 59.3 47.8 57.3 44.8
16 25 56.3 43.7 54.3 40.7
20 25 54.8 41.8 52.8 38.7
25 24 53.4 39.8 51.4 36.8
31.25 24 51.9 37.9 49.9 34.9
62.5 22 47.4 31.9 45.4 28.8
100 21 44.3 27.8 42.3 24.8
155 21 41.5 23.9 39.5 20.9
200 21 39.8 21.8 37.8 18.7
250 18 38.3 19.8 36.3 16.8
300 100±20 17 37.2 18.2 35.2 15.2
350 16 36.2 16.9 34.2 13.9
400 16 35.3 15.7 33.7 12.7
450 16 34.5 14.7 32.5 11.7
500 15 33.8 13.8 31.8 10.8
550 15 33.2 12.9 31.2 9.9

Network Cable Construction (UTP CAT6)

Item No. Con
struction
Conductor
Dimension (mm)
Core dimen
sion (mm)
No. Of
pairs
Nom. OD (mm) Cover type Note
132-1 UTP 0.565 1.03 4 6.3 PVC 250MHZ
132-2 UTP 0.574 1.05 4 6.4 PVC 550MHZ

Network Cable Electrical Characteristics (FTP CAT6)

Frequency (MHZ) Impedance (ohm) RL (dB) Delay deviation (ns/100m) NEXT (dB/100m) ELFEXT (dB/100m) PS NEXT (dB/100m) PS ELFEXT (dB/100m) Velocity of propag
ation (m/s)
1 100±15 20 ≤45 74.3 67.8 72.3 64.8 0.6c
4 23 65.3 61.8 63.3 52.7
8 25 60.3 55.7 58.8 46.7
10 25 59.3 53.8 57.3 44.8
16 25 56.3 49.7 54.3 40.7
20 25 54.8 47.8 52.8 38.7
25 24 53.4 45.8 51.4 36.8
31.25 24 51.9 43.9 49.9 34.9
62.5 22 47.4 37.9 45.4 28.8
100 21 44.3 33.8 42.3 24.8
155 21 41.5 27.8 39.5 20.9
200 21 39.8 25.8 37.8 18.7
250 18 38.3 24.8 36.3 16.8
300 100±20 17 37.2 22.9 35.2 15.2
350 16 36.2 21.8 34.2 13.9
400 16 35.3 20.7 33.7 12.7
450 16 34.5 19.8 32.5 11.7
500 15 33.8 19.0 31.8 10.8
550 15 33.2 18.2 31.2 9.9

Network Cable Construction (FTP CAT6)

Item No. Con
struction
Conductor Dimension (mm) Core dimen
sion (mm)
No. Of pairs Nom. OD (mm) Cover type Note
142-1 FTP 0.574 1.05 4 7.3 PVC 250MHZ
142-2 FTP 0.574 1.05 4 7.3 PVC 550MHZ
Other Products